isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 29 > < Diagram Information and Instructions|Page 27
Page 13
background image

If it is necessary to add a length of wire to the existing harness, be certain to use the same size as the original wire, see Fig. 6.
To find the correct wire size either find the wire on the schematic and convert the metric size to the equivalent AWG size or use an AWG wire
gage. If unsure about the wire size, begin with the largest opening in the wire stripper and work down until a clean strip of the insulation is
removed. Strip approximately 7.5 mm (5/16 in.) of insulation from each wire to be spliced. Be careful to avoid nicking or cutting any of the wires.
Check the stripped wire for nicks or cut strands. If the wire is damaged, repeat this procedure after removing the damaged section.

Fig. 13  Hand Crimp Tool

Fig. 14  Seal Splice Sequence

Step 4: Select and Position the Splice Sleeve 

Select the proper splice sleeve according to wire size. The splice sleeves and tool nests are color coded.
Using a crimp tool, Fig. 13, position the splice sleeve in the proper color nest of the hand crimp tool. Place the splice sleeve in the nest so that the
crimp falls midway between the end of the barrel and the stop.
The sleeve has a stop in the middle of the barrel to prevent the wire from going further, Fig. 14. Close the hand crimper handles slightly to hold the
splice sleeve firmly in the proper nest.

Step 5: Insert Wires into Splice Sleeve and Crimp 

Insert the wire into the splice sleeve until it hits the barrel stop and close the handles of the crimper tightly until the crimper handles open when
released. The crimper handles will not open until the proper amount of pressure is applied to the splice sleeve. Repeat steps 4 and 5 for opposite
end of the splice.

Step 6: Shrink the Insulation around the Splice 

Using a suitable heat gun, apply heat where the barrel is crimped. Gradually move the heat barrel to the open end of the tubing, shrinking the
tubing completely as the heat is moved along the insulation. A small amount of sealant will come out of the end of the tubing when sufficient
shrinking is achieved, Fig. 14.

Splicing Twisted/Shielded Cable

Diagram Information and Instructions|Page 29 > < Diagram Information and Instructions|Page 27