Rodeo (2WD) L4-2559cc 2.6L SOHC (4ZE1) (1991)
Blower Motor: Testing and Inspection
BLOWER MOTOR
1. Disconnect the 2P (B-4) connector from the blower motor.
2. Connect the battery positive terminal to the No. 1 terminal of the blower motor and negative to the No. 2.
3. Be sure to check to see if the blower motor operates correctly.