isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Brake Master Cylinder > < Hydraulic Control Assembly - Antilock Brakes|Removal and Installation|Page 2334
Page 1
background image

Hydraulic Control Assembly - Antilock Brakes: Service and Repair
Disassembly and Reassembly

Disassembly

1. Remove fixing bolts from EHCU.
2. Remove coil integrated module from hydraulic unit.

Reassembly

To reassembly, follow the disassembly steps in the reverse order, noting the following points:
Torque
Fixing bolts: 4 4 Nm (39 inch lbs.)

Brake Master Cylinder > < Hydraulic Control Assembly - Antilock Brakes|Removal and Installation|Page 2334