When connecting the refrigerant line at a block joint, securely insert the projecting portion of the joint portion into the connecting hole on the unit side
and secure with a bolt. Apply the specified compressor oil to the O-rings prior to connecting.

CAUTION:  Compressor (PAG) oil to be used varies according to the compressor model. Be sure to apply oil specified for the model of compressor.

O-rings (2) must be fitted in the groove (1) of refrigerant line.

Insert the nut into the union.

First, tighten the nut by hand as much as possible, then tighten the nut to the specified torque.

Leak Check

Inspection of refrigerant leak

Refrigerant leak may cause an adverse effect not only on the performance and durability of each component of the air-conditioner, but also on the global
atmosphere.

Therefore, it is most important to repair refrigerant leak when there is any leak found.

Leak Check - Repair of Refrigerant Leaks|Page 631 > < Leak Check - Repair of Refrigerant Leaks