Align the located portion (1) of the field coil and compressor.

-

Tighten the mounting screw to the specified torque.

Torque: 5 N.m (44 lb.in) 

2. Connect the lead wire connector with the rubber hold and tighten the screw.

3. Install pulley assembly by using pulley installer J-33940-A (2) and drive handle J-8092 (1).
4. Install snap ring.
5. Install shim (s).

Initial Inspection and Diagnostic Overview|Page 5657 > < Initial Inspection and Diagnostic Overview|Page 5655