isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Fuel Control Heated Oxygen Sensors|Page 571 > < Fuel Control Heated Oxygen Sensors|Page 569
Page 2
background image

-

Bank 2 sensor 2 is mounted behind the left-hand catalytic converter.

3. Disconnect the pigtail from the wiring harness.

IMPORTANT:  The pigtail is permanently attached to the sensor. Be careful not to pull the wires out.

NOTE:  Do not use a torch to remove an HO2S unless the sensor is being replaced. Using a torch could damage the sensor.

4. Remove the sensor from the exhaust pipe.

-

Because of the expansion and contraction of the metal in the exhaust system over time, this may be difficult if the engine temperature is below 
48 °C (120 °F).

INSTALLATION

IMPORTANT:

-

A special anti-seize compound, P/N 5613695, is used on the HO2S threads. This compound consists of glass beads suspended in a liquid graphite
solution. The graphite burns away with engine heat, but the glass beads will remain, making the sensor easier to remove.

-

New or service sensors will already have the compound applied to the threads. If a sensor is removed and is to be reinstalled for any reason, the
threads must have anti-seize compound applied.
1. Apply anti-seize compound or the equivalent to the threads of the oxygen sensor, if necessary.
2. Install the oxygen sensor on the exhaust pipe in its original position.

Fuel Control Heated Oxygen Sensors|Page 571 > < Fuel Control Heated Oxygen Sensors|Page 569