Condenser HVAC: Description and Operation

The condenser assembly is located in front of the radiator. It carries the refrigerant and cooling fins to provide rapid transfer to heat.
Also, it functions to cool the liquefy forcibly high pressure and high-temperature vapor sent from the compressor by the radiator fan (or condenser fan)
or outside air.

A condenser may malfunction in two ways; it may leak, or may be restricted. A condenser restriction will result in excessive compressor discharge
pressure. If a partial restriction is present, the refrigerant expands after passing through the restriction.
Thus, ice or frost may from immediately after the restriction, if air flow through the condenser or radiator is blocked, high discharge pressures will result.
During normal condenser operation, the refrigerant outlet line will be slightly cooler than the inlet line.
The vehicle is equipped with the parallel flow type condenser. A larger thermal transmission area on the inner surface of the tube allows the radiant heat
to increase and the ventilation resistance to decrease.

The refrigerant line connection has a bolt at the block joint, for servicing.