isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

System Relay, HVAC > < Dual Pressure Switch|Page 4259
Page 1
background image

Refrigerant Pressure Sensor / Switch: Service and Repair

REMOVAL

Preparation:

Battery ground cable
Discharge and recover refrigerant

1. Receiver/drier
3. Pressure switch

-

When removing the switch connected part, the connecting part should immediately be plugged or capped to prevent foreign matter from being
mixed into the line.

INSTALLATION

To install, follow the removal steps in the reverse order, noting the following points:

1. O-ring(s) cannot be reused. Always replace with a new one.
2. Be sure to apply new compressor oil to the O-ring when connecting the pressure switch.
3. Tighten the pressure switch to the specified torque.

Torque N.m (lb.in)   13 (113)