carefully connect the module connector.

6. Pass the lead wire through the tabs on the plastic cover (wire protector) of inflator to prevent lead wire from being pinched and perform the

following:
-

Secure the module with one bolt to relieve weight on the connector wire.

-

Tighten the bolts to 8 Nm (69 ft. lbs.) in the sequence as shown in the figure.

-

Connect the battery negative terminal cable.

-

Set ignition to "ON" while watching warning light.

-

Light should flash 7 times and then go off.