isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Regulated Voltage|Page 3637 > < Regulated Voltage|Page 3635
Page 2
background image

Check for continuity across one of the stator coils and stator core. 
If a continuity exists, replace the coil.

Resistance (M Ohms) 

 More than 1

Diode
1. Measure the resistance between each diode terminal and aluminum diode fin in forward and reverse directions with the connection of the tester

leads switched. The diodes are normal if resistance is nearly zero Ohms in one direction and is infinitely high in the other direction.

2. If a diode has no resistance or equal resistance in both directions, it is defective and should be replaced together with the holder.

Brush
1. Measure the brush length.
2. If the measured brush length is less than 5.5 mm, the brush and the brush holder assembly must be replaced.

There is a minimum brush length limit line stamped into the brush.
Length

mm

Standard

18.0 (0.709)

Limit

5.5 (0.217) 

3. Brush soldering precautions.

^

Soldering iron temperature should be between 300 and 350° C.

^

Be sure to use a non-acidic soldering paste.

Regulated Voltage|Page 3637 > < Regulated Voltage|Page 3635