isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Replacement|Page 2686 > < A/T - 4L30E MIL ON/DTC P1870 Stored in PCM|Page 2683
Page 1
background image

Fluid Pump: Service and Repair
Replacement

TOOLS REQUIRED 

^

J-38588 Guide Pin

^

J-38557 Centering Tool

^

Or Equivalent

REMOVAL   

1. Converter housing. Remove five bolts from converter housing.
2. Outer seal ring.
3. Gasket.
4. Wear plate.
5. Oil pump assembly.
6. Oil seal ring.

INSPECTION AND REPAIR

Visual check. If any damage, deformation or local wear is found in a converter housing, outer seal ring, wear plate or oil seal ring, replace it.

INSTALLATION   

1. Oil seal ring.(6) Install oil seal ring using installer. 

^

Torque 3 Nm (26 inch lbs.).

2. Oil pump assembly.(5)
3. Wear plate.(4) Install wear plate onto oil pump assembly.
4. Gasket.(3)
5. Outer seal ring.(2)

6. Converter housing:(1)

a. Install converter housing onto complete oil pump assembly. Align with two short guide pins on outer bolt holes.
b. Loosely install five 13mm bolts.
c. Center converter housing using centering tool. Tighten five inner 13 mm bolts in an alternating pattern. 

^

Torque 20 Nm (15 ft. lbs.)

Replacement|Page 2686 > < A/T - 4L30E MIL ON/DTC P1870 Stored in PCM|Page 2683