isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Adapter Case|Page 2847 > < Adapter Case|Page 2845
Page 3
background image

13. Force motor solenoid.(3)
14. Retainer:(2)

a. Place solenoid terminals pointing towards mating face.
b. Install retainer and bolt. 

^

Torque 10 Nm (87 inch lbs.).

15. Converter clutch solenoid:(1)

a. Install converter clutch solenoid assembly with two O-rings to valve body.
b. Temporarily install bolt. 

NOTE:  When installing adapter case valve body to the case, an earth harness will be added to improve solenoid grounding.

Adapter Case|Page 2847 > < Adapter Case|Page 2845