isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Specifications|Page 3047
Page 1
background image

Condenser HVAC: Service and Repair

Condenser Assembly

Removal

1. Disconnect the battery ground cable.
2. Discharge and recover refrigerant.

-

Refer to Refrigerant Recovery.

3. Remove radiator grille.
4. Remove engine hood front end stay.
5. Remove engine hood lock.

-

Apply setting mark to the engine hood lock fixing position before removing it.

6. Disconnect pressure switch connector.
7. Disconnect refrigerant line.

-

When removing the line connector, the connecting part should immediately be plugged or capped to prevent foreign matter from being mixed
into the line.

8. Remove condenser assembly.

-

Handle with care to prevent damaging the condenser or radiator fin.

Installation

1. Install condenser assembly.

-

If installing a new condenser, be sure to add 30 cc (1.0 fl. oz.) of new compressor oil to a new one.

-

Tighten the condenser fixing bolts to the specified torque.

Torque: 6 N.m (52 lb in)

2. Connect refrigerant line.

-

Tighten the inlet line connector fixing bolt to the specified torque. 

Torque: 15 N.m (11 lb ft)

-

Tighten the outlet line connector fixing bolt to the specified torque. 

Torque: 6 N.m (52 lb in)

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line.

3. Connect pressure switch connector.
4. Install engine hood lock.
5. Install engine hood front end stay.
6. Install radiator grille.

Condenser Fan > < Condenser HVAC|Specifications|Page 3047