isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Evaporator Core > < Evaporator Case|Locations|Page 5110
Page 2
background image

4. Disconnect resistor (2) and electronic thermostat connector (1).
5. Disconnect drain hose.

6. Disconnect refrigerant line.

-

Use a back-up wrench when disconnecting and reconnecting the refrigerant lines.

-

When removing the refrigerant line connected part, the connecting part should immediately be plugged or capped to prevent foreign matter
from being mixed into the line.

7. Remove evaporator assembly.

INSTALLATION

To install, follow the removal steps in the reverse order, noting the following points:

1. To install a new evaporator assembly, add 50 cc (1.7 fl.oz.) of new compressor oil to the new core.

2. Tighten the refrigerant outlet line to the specified torque.

Torque: 25 N.m (18 lb.ft)

3. Tighten the refrigerant inlet line to the specified torque.

Torque: 15 N.m(11 lb.ft)

4. O-rings cannot be reused. Always replace with new ones.

Be sure to apply new compressor oil to the O-rings when connecting lines.

Evaporator Core > < Evaporator Case|Locations|Page 5110