isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

A/C Pressure Switch|Page 422 > < A/C Pressure Switch
Page 1
background image

Refrigerant Pressure Sensor / Switch: Testing and Inspection
Triple Pressure Switch

Triple Pressure Switch (V6, A/T)

1. Disconnect the connector and check for continuity between pressure switch side connector terminals (1) and (2).
2. Reconnect the connector to activate the A/C switch, and check to see if there is continuity between the chassis side connector terminals (3) and (4)

and the fan operates.

A/C Pressure Switch|Page 422 > < A/C Pressure Switch