Common Chamber: Service and Repair

Common Chamber
Removal

1. Disconnect battery ground cable. 

2. Remove air cleaner duct assembly. 
3. Disconnect vacuum booster hose from common chamber. 
4. Disconnect connector from manifold absolute pressure sensor, ion sensing module, throttle position sensor, solenoid valve, electric vacuum

sensing valve, and EGR valve. 

5. Disconnect vacuum hose on canister VSV and positive crankcase ventilation hose, fuel rail assembly with pressure control valve bracket. 
6. Remove ventilation hose from throttle valve and intake duct and remove water hose. 
7. Remove the four throttle body fixing bolts. 
8. Remove exhaust gas recirculation valve assembly fixing bolt, and nut on common chamber and remove EGR valve assembly. 
9. Remove two bolts from common chamber rear side for remove fuel hose bracket.