1. Pull in test

Connect the ground (-) to terminal C and magnetic switch body.
Verify that the pinion pulls out when the battery (+) pole is connected to terminal 50.

2. Hold in test.

Observe that the pinion stays when the lead wire is disconnected from terminal C.

3. Return test.

Connect the ground (-) to terminal 50 and magnetic switch body.
Verify that the pinion pulls out when the battery (+) pole is connected to terminal C and the pinion pulls away when the lead wire is disconnected
from terminal 50.