Condenser Fan Motor Relay: Testing and Inspection

1.

Check continuity between relay terminals 2 and 4. Continuity should not exist.

2.

Apply battery voltage between terminals 1 and 3.

3.

Check continuity between terminals 2 and 4 again. Continuity should exist.