isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Heater Core > < Expansion Valve|Locations|Page 4178
Page 2
background image

-

Lift to remove the upper case.

7. Evaporator core
8. Expansion valve

-

Tear off the insulator carefully.

-

Remove the sensor fixing clip.

-

Use a back-up wrench when disconnecting all refrigerant pipes.

INSTALLATION 

To install, follow the removal steps in the reverse order, noting the following points:

1. The sensor is installed on the core with the clip.
2. The sensor must not interfere with the evaporator core.

3. When install the new evaporator core, install the thermosensor to the evaporator core specified position with the clip.
4. 0-rings cannot be reused. Always replace new ones.
5. Be sure to apply new compressor oil to the O-rings when connecting lines.
6. Be sure to install the sensor and the insulator on the place where they were before.
7. To install a new evaporator core, add 50cc (1.7 fl.oz.) of new compressor oil to a new core.
8. Tighten the refrigerant lines to the specified torque.
9. Apply an adhesive to parting face of lining when assembling evaporator assembly.

Heater Core > < Expansion Valve|Locations|Page 4178