isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

A/T Mode Switch - No Crank In Neutral Position|Page 3813 > < A/T Mode Switch - No Crank In Neutral Position|Page 3811
Page 1
background image

Neutral Safety Switch: Testing and Inspection

Fig. 6  Testing inhibitor switch.

1.

Remove front console, then disconnect two-pin connector from inhibitor switch.

2.

Check for continuity between terminals as shown in Fig. 6.

3.

If continuity is not as specified, replace the inhibitor switch.

A/T Mode Switch - No Crank In Neutral Position|Page 3813 > < A/T Mode Switch - No Crank In Neutral Position|Page 3811