Water valve link rod adjustment
(1) Set the air mix door to the stop position in a counter-clock- wise direction (cold position).
(2) Move the water valve lever to the stop position in a clockwise direction (cold position).
(3) Secure the link rod to the swivel joint with the screw.

-

Mode and temp cable
(1) Attach the control assembly to the instrument panel using screws.
(2) Connect the cable, with the mode selector lever and heater assembly lever set in the OFF position. Secure the outer tube with cable clip.
(3) Connect the cable with the temperature lever and heater lever set in the HOT position, then fix the outer tube with a cable clip. Check all doors

and the water valve. If the doors or the valve are not closing properly, loosen the cable clamp screw at the control and adjust the cable length
as required.

-

Defroster door - The defroster door should be in the defroster position when the control lever is moved to the DEF and HEAT positions. Air is
directed to the defroster outlets.

-

Heat door - In the positions of HEAT and BI-LEVEL, air is directed to the floor outlets. Air is not delivered to other outlets. However, when the
heater is in use, some air is directed to the defroster.

-

Vent door - In the positions of VENT and BI-LEVEL, air is directed out the center and side outlets. Air is not delivered to any other outlets.

-

Air mix door - When the temperature control lever is in the HOT position, hot air is delivered and the water valve is opened fully. In COLD
position, non-heated air is delivered and the water valve is completely closed.