isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

All Technical Service Bulletins for Blower Motor: > < Blower Motor - Water Contamination
Page 2
background image

FIGURE 2

g.

Install the guide into the air cooling hole as shown in Figure 2. Be sure the locating pin in the guide meets the notch in the hole.

h.

Install blower motor and cover.

2.

On vehicles equipped with air conditioning, replace the evaporator drain hose as described in the appropriate Workshop Manual.

PARTS INFORMATION

Part No.

Description

8-94321-873-0

Blower Service Kit

FLAT RATE MANUAL UPDATE INFORMATION

All Technical Service Bulletins for Blower Motor: > < Blower Motor - Water Contamination