Trooper II L4-2559cc 2.6L SOHC (4ZE1) (1989)
Neutral Safety Switch: Testing and Inspection
Inhibitor Switch (A/T Only) - 6 Pin Connector
Inhibitor Switch Testing
INHIBITOR SWITCH
(For Electronic Control Module)
1. With an ohmmeter, check for continuity across the terminals and at the switch positions indicated on the accompanying chart.
2. If continuity is not as indicated, replace inhibitor switch.