isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Diagram Information and Instructions|Page 858 > < Diagram Information and Instructions|Page 856
Page 5
background image

1. With the battery connected, remove the blown fuse.
2. Connect the short finder between the positive battery terminal and the load side fuse terminal.
3. Close all switches in series with the wire that you are troubleshooting.
4. Turn on the short finder This will send pulses of current to the short and create a pulsing magnetic field around the wiring between the fuse box

and the short.

5. Beginning at the fuse box, slowly move the short finder meter along the circuit wiring. The meter will show current pulses through sheet metal and

body trim. As long as the meter is between the fuse and the short, the needle will move with each current pulse. Once you move the meter past the
point of the short, the needle will stop moving. Check around this area to locate the cause of the short circuit.