Trooper LTD V6-3165cc 3.2L SOHC MFI (6VD1) (1997)
Sunroof / Moonroof Limit Switch: Testing and Inspection
The switch sends out a signal when the sun roof reaches the limit stop position 165 mm (6.5 in) before fully closed position.
Check the continuity between the switch terminals. When the result of inspection is found abnormal, repair or replace the switch.