Malfunction Indicator Lamp - A/T: Testing and Inspection

1. CASE it is ON during 2 to 3 seconds at ignition (or when the engine is cranked) but it is OFF after . The indicator is working normally GOTO

DIAGNOSTIC CHECK.

2. CASE it is flashing and the flash is 0.2 seconds ON and 0.2 seconds OFF always when ignition is on (engine cranked or not). This means that

there is a malfunction. GOTO DIAGNOSTIC CHECK.

3. CASE it is staying ON always when ignition is ON.

(1) This means that connection between the Lamp and the PCM is shorted to ground (Fig. 7A-8c).
(2) Verify if instrument panel terminal 7 of connector I-1 is shorted to ground.
(3) Verify if the PCM connector J1 (RED) terminal A14 is shorted to ground.
(4) Verify that the instrument panel terminal 6 of connector I-1 is connected to Battery.
(5) IF problem solved: GOTO CHECK TRANS INDICATOR.

NO: Replace Powertrain Control Module (PCM).

4. CASE it is staying OFF with the ignition ON (engine OFF).

(1) This means that connection between the Lamp and the PCM is shorted to battery or opened.

Malfunction Indicator Lamp - A/T|Description and Operation|Page 3582 > < Malfunction Indicator Lamp - A/T|Description and Operation