Condenser HVAC: Service and Repair

Condenser Assembly And Associated Parts

Condenser Assembly

Removal

1. Disconnect the battery ground cable.
2. Discharge and recover refrigerant. 

-

Refer to Refrigerant Recovery.

3. Remove radiator grille.
4. Remove front bumper assembly. 

-

Refer to Front Bumper in Body Structure section.

5. Remove engine hood front end stay.
6. Disconnect pressure switch connector.
7. Disconnect refrigerant line.

-

When removing the line connector, the connecting part should immediately be plugged or capped to prevent foreign matter from being mixed
into the line.

8. Remove condenser assembly.

-

Handle with care to prevent damaging the condenser or radiator fin.

Installation

1. Install condenser assembly.

-

If installing a new condenser, be sure to add 30 cu.cm (1.0 fl. oz.) of new compressor oil to a new one.

-

Tighten the condenser fixing bolts to the specified torque. 