isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Condenser Fan > < Condenser HVAC|Diagrams|Page 4703
Page 2
background image

Torque: 6 N.m (52 lb.in )

2. Connect refrigerant line.

-

Tighten the inlet line connector fixing bolt to the specified torque.

Torque: 15 N.m (11 lb ft)

-

Tighten the outlet line connector fixing bolt to the specified torque. 

Torque: 6 N.m (52 lb.in )

-

O-rings cannot be reused. Always replace with new ones.

-

Be sure to apply new compressor oil to the O-rings when connecting the refrigerant line.

3. Connect pressure switch connector.
4. Install engine hood front end stay.
5. Install front bumper assembly.
6. Install radiator grille.

Condenser Fan > < Condenser HVAC|Diagrams|Page 4703