isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Power Steering Pressure Switch > < Catalyst Monitor Heated Oxygen Sensor|Page 2274
Page 3
background image

4. Remove the sensor from the exhaust pipe.

Because of the expansion and contraction of the metal in the exhaust system over time, this may be difficult if the engine temperature is below 48 °
C (120 °F)
.

INSTALLATION PROCEDURE

IMPORTANT:A special anti-seize compound on the HO2S threads. This compound consists of glass beads suspended in a liquid graphite solution. The

graphite burns away with engine heat, but the glass beads will remain, making the sensor easier to remove.
New or service sensors will already have the compound applied to the threads. If a sensor is removed and is to be reinstalled for any
reason, the threads must have anti-seize compound applied.

1. Apply anti-seize compound or the equivalent to the threads of the oxygen sensor, if necessary.

2. Install the oxygen sensor on the exhaust pipe in its original position.

Tighten the oxygen sensor to ..........................................................................................................................................................  55 N.m (40 lb ft.).

3. Connect the pigtail to the wiring harness.
4. Connect the negative battery cable.

Power Steering Pressure Switch > < Catalyst Monitor Heated Oxygen Sensor|Page 2274