isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Disassembly and Reassembly|Page 4030 > < Disassembly and Reassembly|Page 4028
Page 1
background image

Starter Motor: Service and Repair
Removal and Installtion

Starter

Removal

1. Battery ground cable.

2. Disconnect Heated O2 Sensor connector (1).
3. Remove exhaust front left pipe (2).

4. Remove heat protector (3).
5. Disconnect starter wiring connector from terminals "B" and "S" (4).
6. Remove starter assembly mounting bolts on inside and outside (5).
7. Remove starter assembly toward the bottom of engine (6).

Installation

1. Install starter assembly (6).
2. Install mounting bolts and tighten bolts to specified torque (5).

Torque:  40 N.m (30 lb ft)

3. Reconnect the connectors to terminals "B" and "S" and tighten Terminals "B" to specified torque.

Torque:  9 N.m (80 lb in)

Disassembly and Reassembly|Page 4030 > < Disassembly and Reassembly|Page 4028