Trooper S V6-3.5L (1998)
1. Connect the high and low charging hoses of the ACR4 (or equivalent) as shown in the image.
2. Recover the refrigerant by following the Manufacturer's Instructions.
3. When a part is removed, put a cap or a plug on the connecting portion so that dust, dirt or moisture cannot get into it.
Refrigerant Recycling
Recycle the refrigerant recovered by J-39500 (ACR4: HFC-134a Refrigerant Recovery/Recycling/Recharging/System) or equivalent.
For the details of the actual operation, follow the steps in the ACR4 (or equivalent) Manufacturer's Instructions.
Evacuation of the Refrigerant System
NOTE: Explained below is a method using a vacuum pump. Refer to the ACR4 (or equivalent) manufacturer's instructions when evacuating the system
with a ACR4 (or equivalent).
Air and moisture in the refrigerant will cause problems in the air conditioning system. Therefore, before charging the refrigerant, be sure to evacuate air
and moisture thoroughly from the system.