4. Remove heater unit.

-

Refer to Heater Unit.

5. Remove duct.
6. Remove case (Mode control) and do not remove link unit at this step.

7. Remove case (Temperature control). Separate two halves of core case.

8. Remove heater core (1).

9. Pull out the mode door while raising up the catch of the door lever.

INSTALLATION

To install, follow the removal steps in the reverse order, noting the following point:

1. Check that each mode door operates properly.