isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Leak Check - Repair of Refrigerant Leaks|Page 4814 > < Leak Check - Repair of Refrigerant Leaks|Page 4812
Page 4
background image

High pressure side

1. Discharger section of compressor
2. Inlet/outlet section of condenser
3. Inlet/outlet section of receiver driver
4. Inlet section of cooling unit

Low pressure side

1. Outlet section of cooling unit
2. Intake section of compressor

Major checking points of refrigerant leak

Compressor

-

Pipe connection

-

Sealing section of shaft

-

Mating section of cylinder

Condenser

-

Pipe connection

-

Welds of condenser body

Receiver drier

-

Pipe connection

-

Attaching section of pressure switch

-

Section around the sight glass

Evaporator unit (cooling unit)

-

Pipe connection

-

Connections of expansion valve

-

Brazed sections of evaporator

NOTE: 

-

The evaporator and expansion valve are contained in the case. Remove the drain hose or the resistor of the cooling unit and insert a leak detector
when checking for any leak.

Flexible hose

-

Pipe connection

-

Caulking section of the hose

-

Hose (cracks, pinholes, flaws)

Pipe

-

Pipe connection

-

Pipe (cracks, flaws)

Charge Valve

NOTE: 

-

The charge valve, which is used to connect the gauge manifold, is normally provided with a resin cap. When the valve inside gets deteriorated, 
refrigerant will leak out.

Leak at Refrigerant Line Connections

1. Check the torque on the refrigerant line fitting and, if too loose, tighten to the specified torque.

-

Use two wrenches to prevent twisting and damage to the line.

-

Do not over tighten.

2. Perform a leak test on the refrigerant line fitting.

Leak Check - Repair of Refrigerant Leaks|Page 4814 > < Leak Check - Repair of Refrigerant Leaks|Page 4812