isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Refrigerant|Service and Repair > < Leak Check - Repair of Refrigerant Leaks|Page 4814
Page 1
background image

Refrigerant: Testing and Inspection
Reading Sight Glass

Reading Sight Glass

The sight glass provides accurate diagnosis only under the following conditions.

If the vehicle can be tested under these conditions, check the sight glass appearance and compare to the chart.

-

Engine speed idle

-

A/C switch "ON"

-

Blower fan operating at high test speed

-

Air source selector lever at "RECIRC"

-

Temperature control lever at coldest position

-

Ambient temperature below 30 °C (86 °F) and humidity below 70% (See NOTE 1)
High side pressure less than 1667.1 kPa (241.7 psi) (See NOTE 2)

NOTE:
1. If the vehicle cannot be moved to a testing location that meets these specifications, then the sight glass cannot be used for diagnosis. You must

discharge and recover the refrigerant, then recharge the system with the specified amount of refrigerant. Then continue checking the system
performance.

NOTE:
2. If the high side pressure is greater than stated, the sight glass cannot be used for diagnosis. You must discharge and recover the refrigerant, then

recharge the system with the specified amount of refrigerant. Then continue checking system performance.

Refrigerant|Service and Repair > < Leak Check - Repair of Refrigerant Leaks|Page 4814