Adjust the control cable.
-

Air source control cable.
1. Slide the control lever to the left ("CIRC" position).
2. Connect the control cable at the "CIRC" position of the link unit of the blower assembly and secure it with the clip.

-

Temperature control cable.
1. Slide the control knob to the left ("MAX COLD" position).
2. Connect the control cable at the "COLD" position of the temperature control link of the heater unit and secure it with the clip.

-

Air select control cable
1. Slide the control knob to the right ("DEFROST" position).
2. Connect the control cable at the "DEFROST" position of the mode control link of the heater unit and secure it with the clip.

Check the control cable operation.