7. Remove shroud.

-

Remove the 3 fixing nuts.

-

Loosen the condenser fixing nut and disconnect the fan motor connector from bracket.

8. Remove fan.

Remove the fan fixing O-ring and plate.

9. Remove condenser fan motor.

Installation 

To install, follow the removal steps in the reverse order, noting the following point:
1. Route the fan motor harness in its previous position, and fix it securely with clip and bracket.