isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Housing Assembly HVAC > < Leak Check - Repair of Refrigerant Leaks|Page 3905
Page 2
background image

To install, follow the removal steps in the reverse order, noting the following points:
1. O-rings cannot be reused. Always replace with new ones.
2. Be sure to apply new compressor oil to the O-rings when connecting lines.
3. Tighten the refrigerant line to the specified torque.

Housing Assembly HVAC > < Leak Check - Repair of Refrigerant Leaks|Page 3905