isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Technician Safety Information|Page 832 > < Technician Safety Information|Page 830
Page 4
background image

CAUTION:  Double-lock type yellow color connectors are used for supplemental restraint system-air bag circuit.
When removing the cable harness, disconnect the connector by unlocking at two places, outside (1) and inside (2). In such a case, do not pull the
wires. Otherwise, wire disconnection may occur.
When connect the double lock type SRS connector, insert the connector completely and lock at outside. Imperfect locking may cause malfunction of
SRS circuit.

Electrical Test Equipment

When using electrical test equipment, insert the probe of the tester into the wire side of the connector. Do not insert the probe of the tester into the
terminal side of the connector, and do not tamper with the connector. Inserting the probe into the terminal side of the connector, and tampering the
connector could cause malfunction of the SRS system or an error in inspection.

Use a probe with the correct tip. Do not insert the probe forcibly.

Use specified service connectors in troubleshooting. Using tools which are not specified standard design could cause an error in inspection due to poor
metal-to-metal contact.

Technician Safety Information|Page 832 > < Technician Safety Information|Page 830