isuzu Workshop Repair Guides

Isuzu Workshop Service and Repair Manuals

Starter Motor|Removal and Installation|Page 3287 > < Inspection and Repair|Page 3284
Page 1
background image

Starter Motor: Service and Repair
Removal and Installation

Removal 

1. Disconnect battery ground cable.
2. Disconnect Heated Heated Oxygen (O2) Sensor connectors (1).

3. Remove exhaust front left pipe (2).
4. Remove heat protector (3).
5. Disconnect starter wiring connector from terminals "B" and "S" (4).
6. Remove starter assembly mounting bolts on inside and outside (5).

7. Remove starter assembly toward the bottom of engine (6).

Installation 
To install, follow the removal steps in the reverse order, noting the following points:

1. Install starter assembly (6).
2. Install mounting bolts and tighten bolts to specified torque (5).

Torque: 40 Nm (30 lb.ft)

Starter Motor|Removal and Installation|Page 3287 > < Inspection and Repair|Page 3284