S-Type (X200) V6-3.0L (2000)
43.
Install and fully tighten the detent spring securing bolt to 10 Nm.
44.
Install new 0-ring, install the solenoid block and install and tighten the solenoid block fixing bolts to 8 Nm (Illustration 14).
45.
Connect the pressure switch electrical connector.
46.
Connect the solenoid block electrical connector.
47.
Install new transmission fluid filter and gasket, and install the fluid pan (see Global Technical Reference GTR Workshop Manual, section: 307-01,
SRO 44.24.07).
Note:
Ensure the manual control lever is in the neutral position. Do NOT carry out the refill procedure shown in the Workshop Manual SRO
44.24.07.
48.
Ensure the manual control lever is in the neutral position.
49.
Install the TR sensor to the manual control lever, install but do not fully tighten the TR sensor securing screws.
50.
Align marks on the TR sensor (Illustration 15).
51.
Final tighten the TR sensor securing screws.
52.
Connect the TR sensor electrical connector.
*Working with an assistant:*
53.
Raise rear of the transmission by hand and reposition the jack under the transmission fluid pan.