Vanden Plas L6-3.6L (1988)
Throttle Valve Cable/Linkage: Adjustments
1.
Loosen cable locknut and manually open throttle linkage to full throttle position.
2.
Measure distance from the outer cable to the crimp, Fig. 3.
3.
Adjust outer cable locknuts until the distance between crimp and outer cable is 44mm for XJS models, and 39 mm for XJ6 models.
4.
Tighten cable locknut, then check that clearance between crimp and outer cable is .70-.80 mm at idle position.