Vanden Plas L6-4.0L (1990)
3.
Turn the bellcrank to "Wide Open Throttle" and move the pointer back towards the bellcrank, (Fig. 3). The pointer MUST align with the "M"
mark.
4.
Adjust the throttle stop screw until the throttle is in the proper position and secure the locknut.
WARRANTY INFORMATION:
Fault Code: 2NJ
Repair Operation Number: 19.20.05 Throttle linkage - adjust
Time Allowance: 0.15 hrs.