Column Adjustment Motors, Fig.1
10.
Column movement switches
a. Examine harness wiring, checking continuity between connector pins as follows:
C/M CM
Switch Pack
RH 'A' post base fuse box
-
Pin 15
Fuse F2
Connector block A
Pin 5
Pin 14
-
Connector block B
Pin 7
Pin 17
-
b. Check resistance values between pins 14 and 15 when switch is operated, in all planes. Values should be as follows; switch up - 220 Ohm,
switch down - 100 Ohm, switch forward 470 Ohm and 820 Ohm.
c. Check for continuity between switch pack pin 17 and ground when mode switch is in auto'.
Column Movement Switches, Fig.1