Vanden Plas (X308) V8-4.0L SC (AJ27) (2001)
13. Disconnect the tank harness connections.
1. If fitted, disconnect the wiring to the accelerometer.
2. Disconnect the wiring to the fuel level sensor harness.
3. Disconnect the wiring to the fuel pump connector.
4. If fitted, disconnect the wiring to the pressure sensor connector.
14. Remove fuel filler latch box drain pipe.
1. Cut and remove the ratchet strap securing the drain pipe to the filler tube.
2. Disconnect the drain pipe from the fuel filler latch box.
3. Pull the drain pipe through the body grommet and remove.
15. Disconnect the vapour outlet pipe.
-
Release the quick-fit coupling.
-
Plug the vapour pipes.