jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

Sliding Roof - Water Intrusion|Page 7376 > < Sliding Roof - Water Intrusion|Page 7374
Page 3
background image

2.

Protect the area around the drive tube opening with absorbent material to catch any debris. Use an air-gun with an extended nozzle, Illustration 3,
to blow into the hole to remove any residual water.

3.

Apply grease to the drive cable, Illustration 4, to fill the tube. Operate the sliding roof control switch to gradually close the panel as far as possible
while applying grease to the moving cable. Repeat the procedure on the opposite cable.

4.

When the drive cable is fully greased, open and close the sliding roof five times to distribute the grease along the tube and dispel any residual
water.

NOTE

The installed SRCM must be used to activate the sliding roof mechanism. If this SRCM is damaged, connect, but do not install, the
replacement SRCM.

5.

While opening and closing the sliding roof, check the SRCM drive opening for water and excess grease being expelled. A suitable absorbent
material should be in position to catch the excess and protect the interior trim.

SEAL AROUND THE TUBE. THE LIFTER BLOCK AND THE GUIDE RAIL

NOTE

Use 3M Auto Sealer 8648 in the following operations.

1.

Thoroughly clean any grease from the area using a suitable solvent.

Sliding Roof - Water Intrusion|Page 7376 > < Sliding Roof - Water Intrusion|Page 7374