jaguar Workshop Repair Guides

Jaguar Workshop Service and Repair Manuals

A/C - Schrader Valve Added to Pressure Cutout Switch|Page 4876 > < A/C - Schrader Valve Added to Pressure Cutout Switch
Page 2
background image

Use only approved recovery equipment

It is illegal to vent refrigerant to the atmosphere.

SERVICE PORT LOCATIONS - ALL 1995 MY SEDAN RANGE VEHICLES

HIGH SIDE PORT

Low SIDE PORT

SEDAN (4.0L)

Compressor outlet pipe - Right side of

Compressor intake pipe - Right side of

RANGE

engine cooling fan duct

engine compartment near bulkhead

XJ12

Compressor outlet flange

Compressor intake pipe - Right side of
engine near timing cover

^

Torque the pressure cutout switches to 3.5 - 6 lb ft (5 - 8 Nm). Do not exceed 6 lb ft

WARNING

DO NOT EXCEED 6 lb ft (8 Nm) TORQUE WHEN TIGHTENING PRESSURE CUTOUT SWITCHES. Overtightening will result in failure of the
Schrader valve causing liquid refrigerant to be discharged when the switch is removed.

VIN 720580 ON - SCHRADER VALVES

^

It is not necessary to depressurize the system on these vehicles when removing the dual (binary) or triple (trinary) pressure cutout switches.

^

Torque the pressure cutout switches to 3.5 - 6 lb ft (5 - 8 Nm). Do not exceed 6 lb ft

A/C - Schrader Valve Added to Pressure Cutout Switch|Page 4876 > < A/C - Schrader Valve Added to Pressure Cutout Switch