SERVICE PORT LOCATIONS - ALL 1995 MV SEDAN RANGE VEHICLES

^ Torque the pressure cutout switches to 3.5 - 6 lb.ft. (5 - 8 N-m). Do not exceed 6 lb.ft.

WARNING:

DO NOT EXCEED 6 lb.ft. [8 N-m) TORQUE WHEN TIGHTENING PRESSURE CUTOUT SWITCHES. Overtightening will result in
failure of the Schrader valve causing liquid refrigerant to be discharged when the switch is removed.

VIN 720580 ON - SCHRADER VALVES

^

It is not necessary to depressurize the system on these vehicles when removing the dual (binary) or triple (trinary) pressure cutout switches.

^

Torque the pressure cutout switches to 3.5 - 6 lb.ft (5 - 8 N-m). Do not exceed 6 lb.ft.