Plenum Chamber - Distorted Drain Valve|Page 2447 > < Plenum Chamber - Distorted Drain Valve
Page 2
background image

2.

If the rubber flap us pushed up, with one side open to allow a clear path for water drain (Illustration 2) or with one side in the correct position,
reposition the flap to the correct position with the fingers. No further action is required.

NOTE:

The rubber flap must be free from the drain tube walls to allow water to drain.

3.

If the rubber flap is pushed up into the drain tube, with both side restricting water flow (Illustration 3), reposition the flap to the correct position
with the fingers and check the ECM for signs of water damage.

ECM WATER DAMAGE CHECK AND REPAIR PROCEDURE

1.

Record all preset radio stations and disconnect the negative battery cable. Remove the lower right side "A" post trim to access the ECM.

2.

Remove the ECM and mounting bracket. Disconnect the ECM harness connectors.

3.

Examine the ECM for signs of water damage.

^

Look for evidence of water stains or marks

^

Examine the ECM housing, connectors and harness for signs of moisture.

4.

If there is any evidence of moisture or previous water leakage in the ECM, connectors or harnesses, replace the ECM.

NOTE:

Connectors, harnesses and surrounding areas must be thoroughly dry before a new ECM is installed.

5.

Reconnect the battery and reset all radio stations and the clock.

PARTS INFORMATION:

DESCRIPTION

PART NUMBER

QTY

ECM - AJ16 engine (naturally aspirated)

LNA 1410AG/102

1

ECM-XJR

LNA 1410CE/401

1