XJ-12 (X300) V12-6.0L (1995)
Alternator: Service and Repair
Removal and Installation
AJ16
Generator Assembly (AJ16)
-
Loosen the generator pivot bolt locknut, the generator to trunnion block securing bolt and the adjusting bolt to the timing cover nut.
-
To release the drive belt tension, undo the adjusting bolt lock nut and the adjusting nut.
-
Remove the drive belt and if applicable the generator. a Refit components in revers order to the removal procedure and adjust the drive belt to the
correct tension.
V12
Generator Assembly (V12)
-
Remove water pump belt for access.
-
Remove compressor and PAS pump drive belt.
-
Remove stabilizer bar brackets and reposition bar to gain access to the generator.
-
Remove and reposition Power Assisted Steering (PAS) pipe for access.
-
Loosen the generator pivot bolt locknut, the bolt securing the trunnion block to the generator adjustment bracket and the adjusting bolt to generator
fixing.