XJ-12 (X300) V12-6.0L (1995)
Accumulator: Service and Repair
Valve Body and Accumulator - Remove For Access & Refit
^
Open the hood and fit suitable fender cover.
^
Raise the vehicle on a ramp.
^
Drain the lubrication system.
^
Remove the fluid pan.
^
Remove the fluid filter.
^
Remove the internal harness, multipin socket O-ring.
^
Remove the internal lubrication pipe.
^
Remove the manual detent spring assembly.
^
Remove the internal dipstick stop.
^
Release and remove the remaining valve body to main case securing bolts (two bolts also secure harness clips).
^
Lower the valve body assembly and place on a clean surface.
^
Remove the front servo piston assembly.
^
Retrieve the check balls from the valve body, see Figs. 1 and 2.
CAUTION: Do net use a magnet.